Home Health Report

Semi-Annual AC Tune-UpJul 8, 2026

27 Tradewind Ter, Palm Beach Shores, FLCare Club · ConnectVisit #1031
87of 100
Monitor

Ed, here's how your home is doing

Your system is running well. The run capacitor is reading slightly low for its rating, so we've flagged it to watch — no action needed today. Everything else is inside its preferred range.

Next: Fall tune-up · October 2026

Score based on Cassidy-defined thresholds for measured performance, component condition, and service history. Drafted with AI assistance; reviewed and approved by your technician.

What we did — photo verified

Evaporator coil as foundBefore
Evaporator coil as found
Coil after chemical cleanAfter
Coil after chemical clean
Drain line flushed, flow verifiedVerified
Drain line flushed, flow verified
Run capacitor tested: 43.6 µFVerified
Run capacitor tested: 43.6 µF
New MERV-8 filter installedAfter
New MERV-8 filter installed
Condenser washed & clearedAfter
Condenser washed & cleared

System readings

Cooling split (ΔT)17.1 °Ftarget 16–22 °FIn spec:
Run capacitor43.6 µFtarget 42.3–47.7 µFWatch:

Slightly low for its rating — flagged to watch at the next visit.

Compressor amp draw15.3 Atarget < 18.9 AIn spec:
Suction pressure113 psitarget 110–130 psiIn spec:
Static pressure0.7 in wctarget < 0.8 in wcIn spec:
JR
Serviced by Justin Reyes
Comfort Technician · EPA 608 Universal · NATE Certified
How was your visit, Ed?

Your feedback goes directly to the Cassidy service team.