Home Health Report

Semi-Annual AC Tune-UpJul 9, 2026

44 Sandpiper Way, North Palm Beach, FLCare Club · ConnectVisit #1033
90of 100
Operating normally

Robert, here's how your home is doing

Your system is operating normally. All readings are inside Cassidy's preferred ranges; the full checklist and photos from today's visit are documented below.

Next: Fall tune-up · October 2026

Score based on Cassidy-defined thresholds for measured performance, component condition, and service history. Drafted with AI assistance; reviewed and approved by your technician.

What we did — photo verified

Evaporator coil as foundBefore
Evaporator coil as found
Coil after chemical cleanAfter
Coil after chemical clean
Drain line flushed, flow verifiedVerified
Drain line flushed, flow verified
Run capacitor tested: 44.7 µFVerified
Run capacitor tested: 44.7 µF
New MERV-8 filter installedAfter
New MERV-8 filter installed
Condenser washed & clearedAfter
Condenser washed & cleared

System readings

Cooling split (ΔT)18.9 °Ftarget 16–22 °FIn spec:
Run capacitor44.7 µFtarget 42.3–47.7 µFIn spec:
Compressor amp draw14.4 Atarget < 18.9 AIn spec:
Suction pressure117 psitarget 110–130 psiIn spec:
Static pressure0.6 in wctarget < 0.8 in wcIn spec:
WB
Serviced by Wilkens Baptiste
Senior Comfort Technician · EPA 608 Universal
How was your visit, Robert?

Your feedback goes directly to the Cassidy service team.