Semi-Annual AC Tune-UpJul 10, 2026

18 Palmetto Ct, Palm Beach Gardens, FLCare Club · ConnectVisit #1035
78of 100
Monitor

Hector, here's how your home is doing

Your system is cooling, but duct static pressure is above target and the cooling split is slightly low — both consistent with restrictive ductwork. A comfort advisor has shared duct options; the system itself checked out fine.

Next: Duct options review follow-up · Scheduled

Score based on Cassidy-defined thresholds for measured performance, component condition, and service history. Drafted with AI assistance; reviewed and approved by your technician.

What we did — photo verified

Evaporator coil as foundBefore
Evaporator coil as found
Coil after chemical cleanAfter
Coil after chemical clean
Drain line flushed, flow verifiedVerified
Drain line flushed, flow verified
Run capacitor tested: 44.2 µFVerified
Run capacitor tested: 44.2 µF
New MERV-8 filter installedAfter
New MERV-8 filter installed
Condenser washed & clearedAfter
Condenser washed & cleared

System readings

Cooling split (ΔT)15.4 °Ftarget 16–22 °FWatch:
Run capacitor44.2 µFtarget 42.3–47.7 µFIn spec:
Compressor amp draw15.1 Atarget < 18.9 AIn spec:
Suction pressure112 psitarget 110–130 psiIn spec:
Static pressure0.9 in wctarget < 0.8 in wcWatch:
JR
Serviced by Justin Reyes
Comfort Technician · EPA 608 Universal · NATE Certified