Home Health Report

Semi-Annual AC Tune-UpJul 11, 2026

300 Flagler Pointe, West Palm Beach, FLCare Club · Detect & PlumbingVisit #1036
85of 100
Monitor

Alice, here's how your home is doing

Your system is running well overall. Two readings are near the edge of their preferred ranges — the cooling split and the run capacitor — so we've flagged both to re-test at your next visit. No action is needed today.

Next: Fall tune-up · October 2026

Score based on Cassidy-defined thresholds for measured performance, component condition, and service history. Drafted with AI assistance; reviewed and approved by your technician.

What we did — photo verified

Evaporator coil as foundBefore
Evaporator coil as found
Coil after chemical cleanAfter
Coil after chemical clean
Drain line flushed, flow verifiedVerified
Drain line flushed, flow verified
Run capacitor tested: 43.1 µFVerified
Run capacitor tested: 43.1 µF
New MERV-8 filter installedAfter
New MERV-8 filter installed
Condenser washed & clearedAfter
Condenser washed & cleared

System readings

Cooling split (ΔT)16.4 °Ftarget 16–22 °FIn spec:
Run capacitor43.1 µFtarget 42.3–47.7 µFWatch:

Near the low edge of spec — we'll re-test at your next visit.

Compressor amp draw15.8 Atarget < 18.9 AIn spec:
Suction pressure114 psitarget 110–130 psiIn spec:
Static pressure0.7 in wctarget < 0.8 in wcIn spec: