What we did — photo verified

Evaporator coil as foundBefore
Evaporator coil as found
Coil after chemical cleanAfter
Coil after chemical clean
Drain line flushed, flow verifiedVerified
Drain line flushed, flow verified
Run capacitor tested: 45.8 µFVerified
Run capacitor tested: 45.8 µF
New MERV-8 filter installedAfter
New MERV-8 filter installed
Condenser washed & clearedAfter
Condenser washed & cleared

System readings

Cooling split (ΔT)20.1 °Ftarget 16–22 °FIn spec:
Run capacitor45.8 µFtarget 42.3–47.7 µFIn spec:
Compressor amp draw13.6 Atarget < 18.9 AIn spec:
Suction pressure121 psitarget 110–130 psiIn spec:
Static pressure0.5 in wctarget < 0.8 in wcIn spec:
JR
Serviced by Justin Reyes
Comfort Technician · EPA 608 Universal · NATE Certified
How was your visit, Denise?

Your feedback goes directly to the Cassidy service team.